If you intend to build or use any other circuit that drives the Fiber Coupled Diode Laser, you should first test them using the simulator.
This can be done using visible f or infrared) combination LEDs, and one or more silicon diodes (to simulate a substantially desired voltage drop 1 and a discrete photodiode to verify the current limiting operation. Adapt to the higher current of the Fiber Coupled Diode Laser, you can use several identical LEDs in parallel with several small matching resistors to ensure equal current sharing, see below.
Note that the sensitivity of this photodiode relative to the LED emission varies considerably depending on its position and orientation. The photodiode and -LEDs- (somewhat like a self-made optoisolator) are stabilized and maximize the response.
Where the Fiber Coupled Diode Laser current is less than 20mA or 30mA. A suitable optocoupler can also be used.
Using this Fiber Coupled Diode Laser simulator will really only be possible to confirm the function of the laser driver current regulator, which is actually not suitable for your Fiber Coupled Diode Laser setting.
Once the circuit is debugged, shut down, and then carefully install the Fiber Coupled Diode Laser. Please double check all connections!
In both cases, the following instruction can be used (assuming that an actual Fiber Coupled Diode Laser is being used):
Set the power of the laser driver to the minimum (usually the maximum potentiometer resistance).
If available, use a regulated power supply with voltage and current limits. Then you can start the voltage from 0 to start, and the current limit just happens to just over the desired laser tube threshold current (plus reset the current drawn, no longer in the Fiber Coupled Diode Laser position test). This always increases the current later.
A voltmeter is connected across the photodiode (PD) terminal and ground, which effectively monitors the associated optical power output.
If there is a separate ammeter, it can be connected in series with the power supply.
Gradually increase the input voltage. Once the Fiber Coupled Diode Laser starts to generate the laser, the PD voltage should rise. This circuit can adjust the PD voltage to the proximity reference. Then, the PD voltage and supply current can be stabilized. If it is sometimes not possible, turn off the power.
This circuit is working properly after the Fiber Coupled Diode Laser is installed and the output power can be moderately increased. However, if there is no laser power meter, you must bear the risk of doing so!
For a Fiber Coupled Diode Laser with visible light, if there is a laser pointer or other laser module of the same wavelength of visible light, as long as the laser beam has the same diameter, the brightness of the two can be compared.
For infrared Fiber Coupled Diode Lasers, the human eye will not work on this. A small red dots from the infrared diodes can not be used as an accurate power output indication.